Home / EU MDR / Technical Documentation
EU MDR 2017/745 · Annex II & III

MDR Technical Documentation for CE Marking

We prepare complete, audit-ready technical documentation under MDR Annex II and III, from device description and GSPR checklist to risk management, verification, clinical evaluation and post-market surveillance, so your Notified Body review runs without avoidable questions.

6sections in Annex II
10–15years you must keep the file
Allrisk classes need one
The basics

What is MDR technical documentation?

MDR technical documentation, also called the technical file, is the evidence that your device meets the General Safety and Performance Requirements of EU MDR 2017/745. Its structure is set out in Annex II for pre-market documentation and Annex III for post-market surveillance.

Every device needs one, whatever its class. For Class IIa, IIb and III devices, the Notified Body reviews it before issuing a CE certificate, and it must be kept up to date for the life of the device.

Proves conformityShows how each Annex I requirement is met, with evidence.
Reviewed by your Notified BodyAssessed before certification and at surveillance audits.
A living documentUpdated with post-market data, design changes and new standards.
Annex II

What MDR Annex II requires

Annex II sets out six sections. Each must be complete, consistent with the others and easy for a reviewer to follow.

SectionWhat it containsWhat reviewers check
1. Device descriptionIntended purpose, variants, accessories, Basic UDI-DI, specifications, previous generations and similar devicesA clear, consistent intended purpose
2. Information suppliedLabels and instructions for use in the languages of the marketsClaims match the clinical and risk evidence
3. Design & manufacturingDesign stages, manufacturing processes, sites and critical suppliersControl of processes and subcontractors
4. GSPRChecklist of Annex I requirements, standards applied and evidence referencesEvery applicable requirement is justified
5. Benefit-risk & risk managementRisk management file under ISO 14971 and benefit-risk analysisRisks reduced as far as possible and linked to labelling
6. Verification & validationPre-clinical tests (biocompatibility, electrical safety, software, sterility, stability, usability) and clinical evaluationTest reports and a CER that support every claim
Annex III

Post-market surveillance documentation

Annex III covers what you must collect and report once the device is on the market. Requirements depend on class.

DocumentApplies toHow often
PMS planAll classesKept current for the life of the device
PMS reportClass IUpdated when necessary
PSURClass IIaAt least every two years
PSURClass IIb and IIIAt least once a year
PMCF plan & reportAll classes, unless justifiedFeeds the CER and PSUR
How it works

How we prepare your technical documentation

A structured process that turns scattered data into a file your Notified Body can review quickly.

  1. 1

    Gap analysis

    Week 1–2

    We review your existing documents, test reports and any MDD file against Annex II and III and list what is missing.

  2. 2

    File structure & plan

    Annex II & III

    We set up the file index and a plan for each missing piece, including testing that still needs to be done.

  3. 3

    Device, labelling & GSPR

    Sections 1–4

    We write the device description, review labels and IFU, document design and manufacturing and build the GSPR checklist.

  4. 4

    Risk & verification

    ISO 14971 · ISO 10993 · IEC 62366-1

    We prepare the risk management file and compile verification and validation evidence, coordinating tests with associated labs.

  5. 5

    Clinical evaluation & PMS

    Annex XIV · Annex III

    We write the CER, PMCF plan, PMS plan and PSUR or PMS report.

  6. 6

    Quality review

    Before submission

    An independent reviewer checks the file for consistency and completeness against Notified Body expectations.

  7. 7

    Submission & query support

    Through to certificate

    We support your Notified Body submission and answer technical documentation questions until closure.

Avoid delays

Common technical documentation gaps

01
Inconsistent intended purposeDifferent wording across the IFU, risk file and CER.
02
GSPR without evidenceRequirements marked as met with no document reference.
03
Weak clinical evidenceEquivalence not justified or claims not supported by data.
04
Risk file not linked to labellingResidual risks missing from warnings and IFU.
05
Outdated standardsTest reports to superseded versions with no gap assessment.
06
Missing PMS documentsNo PMS plan, PMCF plan or PSUR schedule in place.
Our service

Our technical documentation services

Technical file compilationComplete Annex II and III files for all classes.
MDD to MDR file upgradeGap analysis and remediation of legacy files.
GSPR checklistRequirement-by-requirement evidence mapping.
Risk management fileISO 14971 risk analysis and benefit-risk report.
CER, PMCF & PSURClinical and post-market documents that stay consistent.
Notified Body query responsesClear, evidence-based answers to deficiency findings.
FAQ

MDR technical documentation FAQs

What is MDR technical documentation?

It is the set of documents, often called the technical file, that proves your device meets EU MDR 2017/745. Its content is set out in Annex II (technical documentation) and Annex III (post-market surveillance documentation).

Do Class I devices need technical documentation?

Yes. Every class needs full Annex II and III documentation. For Class I devices it is not reviewed by a Notified Body (unless sterile, measuring or reusable surgical), but it must be ready for competent authorities on request.

How long must technical documentation be kept?

Under MDR Article 10(8), at least 10 years after the last device covered by the EU Declaration of Conformity is placed on the market, and at least 15 years for implantable devices.

What is the GSPR checklist?

It is a table showing how your device meets each General Safety and Performance Requirement in MDR Annex I, with the standards applied and references to the evidence in your file. Notified Bodies review it closely.

Can you upgrade our MDD technical file to MDR?

Yes. We run a gap analysis of your MDD file against Annex II and III, then update the GSPR checklist, risk file, clinical evaluation, labels and PMS documentation to meet MDR.

How long does it take to prepare MDR technical documentation?

It depends on device class and how much test and clinical data already exists. With test reports in place, a complete file typically takes 8 to 16 weeks.

Want your technical file checked before submission?

Send us your device details using the form below and we'll tell you what's missing at no cost.